summaryrefslogtreecommitdiff
path: root/vendor/golang.org/x/sys/windows/zsyscall_windows.go
diff options
context:
space:
mode:
authorTomSweeneyRedHat <tsweeney@redhat.com>2019-11-13 10:30:08 -0500
committerTomSweeneyRedHat <tsweeney@redhat.com>2019-11-13 10:57:19 -0500
commit6003033adae775f1d725b05231a246a4462ae669 (patch)
treec570c523df92c3c0fb4b704c5c45b0de6603b7d6 /vendor/golang.org/x/sys/windows/zsyscall_windows.go
parentde32b89eff0928abdef9d85a420b65d8865e737e (diff)
downloadpodman-6003033adae775f1d725b05231a246a4462ae669.tar.gz
podman-6003033adae775f1d725b05231a246a4462ae669.tar.bz2
podman-6003033adae775f1d725b05231a246a4462ae669.zip
Bump to Buildah v1.11.5
Bump to Buildah v1.11.5. Most notably changes to the podman build `--pull` functionality. `--pull=true` and `--pull=false` now work as Docker does, `--pull-never` added to supply the functionality of the old `--pull=false`. Signed-off-by: TomSweeneyRedHat <tsweeney@redhat.com>
Diffstat (limited to 'vendor/golang.org/x/sys/windows/zsyscall_windows.go')
-rw-r--r--vendor/golang.org/x/sys/windows/zsyscall_windows.go64
1 files changed, 64 insertions, 0 deletions
diff --git a/vendor/golang.org/x/sys/windows/zsyscall_windows.go b/vendor/golang.org/x/sys/windows/zsyscall_windows.go
index 9c448be31..4a9893242 100644
--- a/vendor/golang.org/x/sys/windows/zsyscall_windows.go
+++ b/vendor/golang.org/x/sys/windows/zsyscall_windows.go
@@ -234,6 +234,10 @@ var (
procSetVolumeLabelW = modkernel32.NewProc("SetVolumeLabelW")
procSetVolumeMountPointW = modkernel32.NewProc("SetVolumeMountPointW")
procMessageBoxW = moduser32.NewProc("MessageBoxW")
+ procExitWindowsEx = moduser32.NewProc("ExitWindowsEx")
+ procInitiateSystemShutdownExW = modadvapi32.NewProc("InitiateSystemShutdownExW")
+ procSetProcessShutdownParameters = modkernel32.NewProc("SetProcessShutdownParameters")
+ procGetProcessShutdownParameters = modkernel32.NewProc("GetProcessShutdownParameters")
procCLSIDFromString = modole32.NewProc("CLSIDFromString")
procStringFromGUID2 = modole32.NewProc("StringFromGUID2")
procCoCreateGuid = modole32.NewProc("CoCreateGuid")
@@ -2584,6 +2588,66 @@ func MessageBox(hwnd Handle, text *uint16, caption *uint16, boxtype uint32) (ret
return
}
+func ExitWindowsEx(flags uint32, reason uint32) (err error) {
+ r1, _, e1 := syscall.Syscall(procExitWindowsEx.Addr(), 2, uintptr(flags), uintptr(reason), 0)
+ if r1 == 0 {
+ if e1 != 0 {
+ err = errnoErr(e1)
+ } else {
+ err = syscall.EINVAL
+ }
+ }
+ return
+}
+
+func InitiateSystemShutdownEx(machineName *uint16, message *uint16, timeout uint32, forceAppsClosed bool, rebootAfterShutdown bool, reason uint32) (err error) {
+ var _p0 uint32
+ if forceAppsClosed {
+ _p0 = 1
+ } else {
+ _p0 = 0
+ }
+ var _p1 uint32
+ if rebootAfterShutdown {
+ _p1 = 1
+ } else {
+ _p1 = 0
+ }
+ r1, _, e1 := syscall.Syscall6(procInitiateSystemShutdownExW.Addr(), 6, uintptr(unsafe.Pointer(machineName)), uintptr(unsafe.Pointer(message)), uintptr(timeout), uintptr(_p0), uintptr(_p1), uintptr(reason))
+ if r1 == 0 {
+ if e1 != 0 {
+ err = errnoErr(e1)
+ } else {
+ err = syscall.EINVAL
+ }
+ }
+ return
+}
+
+func SetProcessShutdownParameters(level uint32, flags uint32) (err error) {
+ r1, _, e1 := syscall.Syscall(procSetProcessShutdownParameters.Addr(), 2, uintptr(level), uintptr(flags), 0)
+ if r1 == 0 {
+ if e1 != 0 {
+ err = errnoErr(e1)
+ } else {
+ err = syscall.EINVAL
+ }
+ }
+ return
+}
+
+func GetProcessShutdownParameters(level *uint32, flags *uint32) (err error) {
+ r1, _, e1 := syscall.Syscall(procGetProcessShutdownParameters.Addr(), 2, uintptr(unsafe.Pointer(level)), uintptr(unsafe.Pointer(flags)), 0)
+ if r1 == 0 {
+ if e1 != 0 {
+ err = errnoErr(e1)
+ } else {
+ err = syscall.EINVAL
+ }
+ }
+ return
+}
+
func clsidFromString(lpsz *uint16, pclsid *GUID) (ret error) {
r0, _, _ := syscall.Syscall(procCLSIDFromString.Addr(), 2, uintptr(unsafe.Pointer(lpsz)), uintptr(unsafe.Pointer(pclsid)), 0)
if r0 != 0 {