diff options
Diffstat (limited to 'vendor/golang.org/x/sys/windows/zsyscall_windows.go')
-rw-r--r-- | vendor/golang.org/x/sys/windows/zsyscall_windows.go | 64 |
1 files changed, 64 insertions, 0 deletions
diff --git a/vendor/golang.org/x/sys/windows/zsyscall_windows.go b/vendor/golang.org/x/sys/windows/zsyscall_windows.go index 9c448be31..4a9893242 100644 --- a/vendor/golang.org/x/sys/windows/zsyscall_windows.go +++ b/vendor/golang.org/x/sys/windows/zsyscall_windows.go @@ -234,6 +234,10 @@ var ( procSetVolumeLabelW = modkernel32.NewProc("SetVolumeLabelW") procSetVolumeMountPointW = modkernel32.NewProc("SetVolumeMountPointW") procMessageBoxW = moduser32.NewProc("MessageBoxW") + procExitWindowsEx = moduser32.NewProc("ExitWindowsEx") + procInitiateSystemShutdownExW = modadvapi32.NewProc("InitiateSystemShutdownExW") + procSetProcessShutdownParameters = modkernel32.NewProc("SetProcessShutdownParameters") + procGetProcessShutdownParameters = modkernel32.NewProc("GetProcessShutdownParameters") procCLSIDFromString = modole32.NewProc("CLSIDFromString") procStringFromGUID2 = modole32.NewProc("StringFromGUID2") procCoCreateGuid = modole32.NewProc("CoCreateGuid") @@ -2584,6 +2588,66 @@ func MessageBox(hwnd Handle, text *uint16, caption *uint16, boxtype uint32) (ret return } +func ExitWindowsEx(flags uint32, reason uint32) (err error) { + r1, _, e1 := syscall.Syscall(procExitWindowsEx.Addr(), 2, uintptr(flags), uintptr(reason), 0) + if r1 == 0 { + if e1 != 0 { + err = errnoErr(e1) + } else { + err = syscall.EINVAL + } + } + return +} + +func InitiateSystemShutdownEx(machineName *uint16, message *uint16, timeout uint32, forceAppsClosed bool, rebootAfterShutdown bool, reason uint32) (err error) { + var _p0 uint32 + if forceAppsClosed { + _p0 = 1 + } else { + _p0 = 0 + } + var _p1 uint32 + if rebootAfterShutdown { + _p1 = 1 + } else { + _p1 = 0 + } + r1, _, e1 := syscall.Syscall6(procInitiateSystemShutdownExW.Addr(), 6, uintptr(unsafe.Pointer(machineName)), uintptr(unsafe.Pointer(message)), uintptr(timeout), uintptr(_p0), uintptr(_p1), uintptr(reason)) + if r1 == 0 { + if e1 != 0 { + err = errnoErr(e1) + } else { + err = syscall.EINVAL + } + } + return +} + +func SetProcessShutdownParameters(level uint32, flags uint32) (err error) { + r1, _, e1 := syscall.Syscall(procSetProcessShutdownParameters.Addr(), 2, uintptr(level), uintptr(flags), 0) + if r1 == 0 { + if e1 != 0 { + err = errnoErr(e1) + } else { + err = syscall.EINVAL + } + } + return +} + +func GetProcessShutdownParameters(level *uint32, flags *uint32) (err error) { + r1, _, e1 := syscall.Syscall(procGetProcessShutdownParameters.Addr(), 2, uintptr(unsafe.Pointer(level)), uintptr(unsafe.Pointer(flags)), 0) + if r1 == 0 { + if e1 != 0 { + err = errnoErr(e1) + } else { + err = syscall.EINVAL + } + } + return +} + func clsidFromString(lpsz *uint16, pclsid *GUID) (ret error) { r0, _, _ := syscall.Syscall(procCLSIDFromString.Addr(), 2, uintptr(unsafe.Pointer(lpsz)), uintptr(unsafe.Pointer(pclsid)), 0) if r0 != 0 { |